Перегляд за автором "Komarov, A.D."

Сортувати за: Порядок: Результатів:

  • Bondarenko, J.S.; Chmyga, A.A.; Dreval, M.B.; Eliseev, L.G.; Khrebtov, S.M.; Komarov, A.D.; Kozachok, A.S.; Krupnik, L.I.; Melnikov, A.V.; Nedzelskij, I.S. (Вопросы атомной науки и техники, 2002)
  • Zhezhera, A.I.; Chmyga, A.A.; Deshko, G.N.; Kozachek, A.S.; Komarov, A.D.; Krupnik, L.I.; Khrebtov, S.M. (Вопросы атомной науки и техники, 2016)
    This paper describes the new version of electronic control unit for ion beam forming in the Heavy Ion Beam Probing (HIBP) diagnostics. This improved unit was developed, manufactured, installed and tested on HIBP system for ...
  • Bondarenko, I.S.; Chmyga, A.A.; Deshko, G.N.; Dreval, N.B.; Khrebtov, S.M.; Komarov, A.D.; Kozachek, A.S.; Krupnik, L.I.; Nedzelskiy, I.S. (Вопросы атомной науки и техники, 2002)
  • Moiseenko, V.E.; Tarasov, I.K.; Tarasov, M.I.; Sitnikov, D.A.; Korovin, V.B.; Komarov, A.D.; Kozachek, A.S.; Krupnik, L.I.; Zhezhera, A.I.; Pavlichenko, R.O.; Zamanov, N.V.; Kulaga, A.Ye.; Shapoval, A.N.; Lytova, M.A.; Maznichenko, S.M.; Solodovchenko, S.I.; Shtan', A.F. (Вопросы атомной науки и техники, 2014)
    The possibilities of stimulation and complete suppression of the runaway electrons flow in the experiments at Uragan-2M setup were investigated. The flow stimulation was carried out by producing additional free charged ...
  • Bondarenko, I.S.; Chmyga, A.A.; Dreval, N.B.; Khrebtov, S.M.; Komarov, A.D.; Kozachok, A.S.; Krupnik, L.I.; Eliseev, L.G.; Mavrin, V.A.; Melnikov, A.V.; Rasumova, K.A.; Zimeleva, L.G.; Hidalgo, C.; Garcia-Cortes, I.; Coelho, P.; Cunha, M.; Goncalves, B.; Malaquias, A.; Nedzelskiy, I.S.; Varandas, C.A.F. (Вопросы атомной науки и техники, 2000)
  • Komarov, A.D.; Chmyga, A.A.; Chechkin, V.V.; Grigor’eva, L.I.; Deshko, G.N.; Kozachek, A.S.; Krupnik, L.I.; Khrebtov, S.M.; Maznichenko, S.M.; Mironov, Yu.K.; Romanov, V.S.; Zhezhera, A.I. (Вопросы атомной науки и техники, 2016)
    First estimations of plasma electric potential and density in URAGAN -2M (U-2M) torsatron were done by the Heavy Ion Beam Probing Diagnostic (HIBP). The estimated plasma potential has the negative potential value of -(80…195) ...
  • Dreval, N.B.; Krupnik, L.I.; Chmyga, A.A.; Khrebtov, S.M.; Komarov, A.D.; Kozachek, A.S.; Hidalgo, C.; Melnikov, A.V.; Eliseev, L.G. (Вопросы атомной науки и техники, 2005)
    Features of heavy ion beam probe application to stellarator-like devices have been connected with specific stellarator characteristics: zero (negligible) plasma current, relatively high poloidal and stray magnetic fields, ...
  • Chmyga, A.A.; Deshko, G.N.; Dreval, N.B.; Khrebtov, S.M.; Komarov, A.D.; Kozachek, A.S.; Krupnik, L.I.; Melnikov, A.V.; Perfilov, S.V.; Galvao, R.M.O.; Kuznetsov, Yu.K. (Вопросы атомной науки и техники, 2003)
    The Heavy Ion Beam Probe (HIBP) diagnostic is known as a unique tool for the direct plasma electric potential measurements. It gives also information on plasma density, temperature and current profile. The method is based ...
  • Melnikov, A.V.; Krupnik, L.I.; Barcala, J.M.; Bravo, A.; Chmyga, A.A.; Deshko, G.N.; Drabinskij, M.A.; Eliseev, L.G.; Hidalgo, C.; Khabanov, P.O.; Kharchev, N.K.; Komarov, A.D.; Kozachek, A.S.; Khrebtov, S.M.; Lopez, J.; Lysenko, S.E.; Molinero, A.; de Pablos, J.L.; Ufimtsev, M.V.; Zenin, V.N.; Zhezhera, A.I. (Вопросы атомной науки и техники, 2017)
    Heavy ion beam probing (HIBP) is a unique diagnostic for core plasma potential. It operates in the T-10 tokamak and TJ-II flexible heliac. Multi-slits energy analyzers provide simultaneously the data on plasma potential φ ...
  • Bondarenko, I.S.; Chmyga, A.A.; Deshko, G.N.; Komarov, A.D.; Kozachok, A.S.; Krupnik, L.I.; Khrebtov, S.M.; Zhezhera, A.I. (Вопросы атомной науки и техники, 2009)
    The project of the Heavy Ion Beam Probe (HIBP) plasma diagnostic system for stellarator Uragan-2M is presented. The device Uragan-2M is the flexible torsatron machine with small helical ripples and considerably high size ...
  • Bondarenko, I.S.; Chmyga, A.A.; Deshko, G.N.; Komarov, A.D.; Kozachek, A.S.; Krupnik, L.I.; Khrebtov, S.M.; Taschev, Yu.I.; Zhezhera, A.I. (2010)
    The testing and first operations of the Heavy Ion Beam Probe (HIBP) plasma diagnostic injectors for stellarator Uragan-2M and TJ-ІІ is presented in this work. The increasing of plasma density in modern fusion devices up ...
  • Bondarenko, I.S.; Chmyga, A.A.; Deshko, G.N.; Komarov, A.D.; Kozachok, A.S.; Krupnik, L.I.; Khrebtov, S.M.; Zhezhera, A.I.; Podoba, Y.Ya.; Otte, M.; Wagner, F.; Melnikov, A.V.; Perfilov, S.V.; Schubert, M. (Вопросы атомной науки и техники, 2009)
    The heavy ion beam probe (HIBP) is a non-perturbing diagnostic, which allows to determine the spatial distributions of the main plasma parameters such as plasma potential, density, electron temperature and poloidal magnetic ...
  • Krupnik, L.I.; Melnikov, A.V.; Hidalgo, C.; Chmyga, A.A.; Eliseev, L.G.; Ascasibar, E.; Estrada, T.; Komarov, A.D.; Kozachek, A.S.; Liniers, M.; Lysenko, S.E.; Mavrin, V.A.; Ochando, M.A.; de Pablos, J.L.; Pedrosa, M.A.; Perfilov, S.V.; Tabares, F.; Zhezhera, A.I. (Вопросы атомной науки и техники, 2011)
    TJ-II stellarator by HIBP diagnostics has been performed. The following similar features of potential were found: the scale of several hundred Volts; the negative sign for densities ne>1×10¹⁹ m⁻³ and comparable values ...
  • Bondarenko, I.S.; Chmyga, A.A.; Deshko, G.N.; Komarov, A.D.; Kozachok, A.S.; Krupnik, L.I.; Khrebtov, S.M.; Taschev, Yu.I.; Zhezhera, A.I. (Вопросы атомной науки и техники, 2011)
    The results of solid-state thermo-ionic emitters of Cs⁺ and Tl⁺ ions investigations are presented. These emitters are planned to use in heavy ion beam diagnostic system for “Uragan-2M” stellarator. According to estimations ...
  • Zhezhera, A.I.; Chmyga, A.А.; Deshko, G.N.; Eliseev, L.G.; Hidalgo, C.; Komarov, A.D.; Kozachek, A.S.; Krupnik, L.I.; Melnikov, A.V.; de Pablos, J.L.; Perfilov, S.V. (Вопросы атомной науки и техники, 2017)
    The unique capabilities of the dual HIBP system allow the investigation of multi-scale mechanisms to be expanded from the plasma edge to the plasma core in the TJ-II stellarator. Experiments with combined NBI and ECRH ...
  • Castejón, F.; Ascasíbar, E.; Alejaldre, C.; Alonso, J.; Almoguera, L.; Baciero, A.; Balbín, R.; Blanco, E.; Blaumoser, M.; Botija, J.; Brañas, B.; Cappa, A.; Carrasco, R.; Cepero, J.R.; Chmyga, A.A.; Doncel, J.; Dreval, N.B.; Eguilior, S.; Eliseev, L.; Estrada, T.; Fedyanin, O.; Fernández, A.; Fontdecaba, J.M.; Fuentes, C.; García, A.; García-Cortés, I.; Gonçalves, B.; Guasp, J.; Herranz, J.; Hidalgo, A.; Hidalgo, C.; Jiménez, J.A.; Kirpitchev, I.; Khrebtov, S.M.; Komarov, A.D.; Kozachok, A.S.; Krupnik, L.; Lapayese, F.; Likin, K.; Liniers, M.; López-Bruna, D.; López-Fraguas, A.; López-Rázola, J.; López-Sánchez, A.; de la Luna, E.; Malaquias, A.; Martín, R.; Medrano, M.; Melnikov, A.V.; Méndez, P.; McCarthy, K.J.; Medina, F.; van Milligen, B.; Nedzelskiy, I.S.; Ochando, M.; Pacios, L.; Pastor, I.; Pavlov, S.S.; Pedrosa, M.A.; de la Peña, A.; Petrov, A.; Petrov, S.; Portas, A.; Romero, J.; Rodríguez-Rodrigo, L.; Salas, A.; Sánchez, E.; Sánchez, J.; Sarksian, K.; Schchepetov, S.; Skvortsova, N.; Tabarés, F.; Tafalla, D.; Tribaldos, V.; Varandas, C.F.A.; Vega, J.; Zurro, B. (Вопросы атомной науки и техники, 2002)
    Transport properties of TJ-II are explored performing perturbative experiments and taking advantage of TJ-II flexibility. Rotational transform can be varied in a wide range, which allows one to introduce low order rationals ...
  • Krupnik, L.I.; Melnikov, A.V.; Hidalgo, C.; Eliseev, L.G.; Chmyga, A.A.; Komarov, A.D.; Kozachok, A.S.; Perfilov, S.V.; Lysenko, L.G.; Zhezhera, A.I.; Pedrosa, M.A.; de Pablos, J.L. (Вопросы атомной науки и техники, 2009)
    Heavy Ion Beam Probe diagnostics is used in TJ-II stellarator to study directly the plasma electric potential with a good spatial (up to 1cm) and temporal (up to 2 µs ) resolution. Low density (ne = (0.3…0.5)×1019 m –3) ...
  • Melnikov, A.V.; Vershkov, V.A.; Grashin, S.A.; Eliseev, L.G.; Lysenko, S.E.; Mavrin, V.A.; Merezhkin, V.G.; Perfilov, S.V.; Shelukhin, D.A.; Shurygin, R.V.; Krupnik, L.I.; Komarov, A.D.; Kozachek, A.S.; Zhezhera, A.I. (2010)
    Plasma potential, its oscillations and turbulence rotation were studied on T-10 in a wide range of ohmic and ECRH regimes. The potential has negative sign over the whole plasma cross section. Broadband turbulence tends to ...
  • Chmyga, A.A.; Deshko, G.N.; Komarov, A.D.; Kozachek, A.S.; Krupnik, L.I.; Khrebtov, S.M.; Tashchev, Yu.I.; Zhezhera, A.I. (Вопросы атомной науки и техники, 2012)
    The development of light ion injector and neutralizer for the BES plasma diagnostic system and its first experimental results are presented in this work. This injector will be used for neutral beam plasma diagnostic systems. ...
  • Zhezhera, A.I.; Chmyga, A.A.; Deshko, G.N.; Krupnik, L.I.; Kozachek, A.S.; Komarov, A.D.; Khrebtov, S.M.; Maznichenko, S.M.; Tashchev, Yu.I.; Lesnyakov, G.G.; Tarasov, I.K.; Perfilov, S.V. (Вопросы атомной науки и техники, 2015)
    The Heavy Ion Beam Probing (HIBP) diagnostic system has been installed and operates now on the Uragan-2M torsatron for the first time in Ukraine. The cesium ion beam with energy range of 17…120 keV and ion current of 10…150 ...